Volumetric flow rate:

(T1) Mold filling hood - 1650 cfm

(T2) Launder hood - 2460 cfm

(T3) Metal tapping hood - 3660 cfm

(T5, T6, T7, T8) Refining kettle hoods -  4700 cfm

(T9, T10) Skip hoist furnace charging hood - 12100 cfm

(T12) Slag tapping hood - 4540 cfm

(T14) Skip hoist hoods (top and bottom) - 3930 cfm

(T15) Slot hood over furnace access doors - 1940 cfm

Exhaust pickups for new kettle hoods - 2940 cfm

Discharge from slag tapping baghouse - 5000 cfm

Inlet to main exhaust fan for smelter exhaust ventilation system - 41700 cfm

Proceedings of the Symposium on Occupational Health Hazard Control Technology in the Foundry and Secondary Non-Ferrous Smelting Industries
, U.S. Department of Health and Human Services, NIOSH Publication No. 81-114 (1981).